212iLW/242iLW Standalone Keypad
Installation/Programming Manual
Document # 6050700, Rev. 1.1, D2d
10
5.4 Shunting a Normally Closed Zone
Use the following steps to use the keypad to shunt a normally closed
zone:
1. Connect the blue wire (common) to the common connection on
the door position switch.
2. Connect the green wire (normally open) to the normally closed
connection on the door position switch.
Fi
g
ure 6 Wirin
g
the Ke
y
pad to an Electric St
r
ike
(
Fail-Secure
)
Figure 7 Shunting a Normally Closed Zone